Is water quality important for system performance?
Yes, water quality is critically important for the performance, efficiency, reliability, and service life of a water-cooled screw chiller system.In water-cooled HVAC systems—especially high-capacity, long-running equipment such as Aurashu water-cooled screw chillers—water quality directly affects heat transfer efficiency, operating stability, maintenance frequency, and overall lifecycle cost.1. Why water quality matters in water-cooled chillersA water-cooled screw chiller relies on two major water circuits:Chilled water loop (supplying cooling to terminals or processes)Condenser water loop (rejecting heat via cooling tower)In both circuits, water flows continuously through heat exchangers, pipes, valves, and pumps. Poor water quality can lead to scaling, corrosion, fouling, and biological growth, all of which reduce system performance and may cause serious equipment damage over time.Aurashu designs its water-cooled screw chillers for high-efficiency and long-term industrial operation, but even the most robust equipment requires properly managed water conditions to perform at its full potential.2. Impact of poor water quality on system performance(1) Reduced heat transfer efficiencyScale deposits (calcium carbonate, magnesium salts) form insulating layers on heat exchanger tubesEven a thin layer of scale can significantly reduce heat transferChiller must run longer or at higher load → increased energy consumptionIn Aurashu chillers, precision-machined shell-and-tube heat exchangers are designed for optimal thermal performance, but scale buildup directly offsets these advantages.(2) Increased energy consumptionFouled heat exchangers raise condensing temperatureCompressor power increases to maintain cooling capacitySystem COP (Coefficient of Performance) declinesOver long operating periods, poor water quality can increase annual energy costs by 10–30% or more.(3) Corrosion and equipment damageImproper pH, high dissolved oxygen, or aggressive ions (chlorides, sulfates) accelerate corrosionCorrosion can cause:Tube leakageReduced pressure resistanceRefrigerant contaminationPremature heat exchanger failureAurashu offers optional anti-corrosion materials, tube coatings, and water-side protection designs, but correct water treatment remains essential.(4) Biological fouling and blockageAlgae, bacteria, and biofilm can form in untreated water systemsBiofouling reduces flow area and heat exchange efficiencyCan cause unpleasant odors, hygiene issues, and system instabilityThis is especially critical in cooling tower condenser water systems.3. Key water quality parameters to controlAurashu recommends managing water quality according to industry standards and project-specific requirements, typically including:pH value (usually 6.5–8.5)Hardness (calcium & magnesium content)Total dissolved solids (TDS)Chloride and sulfate concentrationDissolved oxygenMicrobial contentSuspended solidsMaintaining these parameters within acceptable limits ensures stable chiller operation and extends service life.4. Aurashu design features supporting water quality managementAurashu water-cooled screw chillers are engineered with water quality considerations in mind:High-quality shell-and-tube heat exchangersOptimized tube velocity to reduce fouling riskOptional cupronickel, stainless steel, or enhanced copper tubesIntelligent control system with temperature and pressure monitoringCompatibility with standard water treatment and filtration systemsHowever, equipment design alone cannot replace proper water treatment.5. Recommended water treatment solutionsFor optimal long-term performance, Aurashu strongly recommends the following measures:Water softening (to reduce scale formation)Chemical water treatment (corrosion inhibitors, biocides)Side-stream filtration (to remove suspended solids)Automatic blowdown systems (for cooling towers)Regular water quality testing and reportingThese measures significantly reduce maintenance costs and unplanned downtime.6. Impact on maintenance and lifecycle costGood water quality results in:Longer heat exchanger lifeFewer tube cleaningsReduced compressor stressStable capacity outputLower total cost of ownership (TCO)Poor water quality, by contrast, often leads to:Frequent shutdownsEmergency repairsReduced system reliabilityShortened equipment lifespanFor large commercial buildings, industrial plants, data centers, and hospitals using Aurashu chillers, water quality management is a critical operational strategy, not an optional extra.7. Aurashu service support and guidanceAurashu provides:Water quality guidelines during project designCoordination with EPC contractors and water treatment suppliersCustom material selection for special water conditionsOperation & maintenance recommendations tailored to local water qualityThis ensures that each chiller system delivers stable, efficient, and reliable performance throughout its lifecycle.